BENTEL J524F PDF

be equipped with a BENTEL BA ( V – 4 A) Linear power supply or BENTEL SECURITY srl reserves the right to change the technical features of this . bentel jf. hello i have a fire security system bentel jf and i cant find the instaler manual or usser manual please can anibody help my thx. Bentel JF tulekahju signakeskus в категории: Рабочее оборудование, строительство, Другие машины и оборудование (ID номер.

Author: Kejora Moogugis
Country: Liechtenstein
Language: English (Spanish)
Genre: Software
Published (Last): 10 November 2012
Pages: 454
PDF File Size: 16.39 Mb
ePub File Size: 9.19 Mb
ISBN: 672-8-37908-452-1
Downloads: 24972
Price: Free* [*Free Regsitration Required]
Uploader: Vudogore

Bentel j424 manual pdf

Apparently the panel needs to see fire zones clear normally before the trouble will clear. I still have a fault 5 showing zone 1 trouble, have toggled the EOL and NC option in sectionno change.

You sounded like you were familier with the system, so it never occurred fo me the check that you had let the exit delay time out Tub pump air tube came off. Thanks for all your help! BB code is On.

Bentel Security | User Manuals

J5524f In General Chats and Discussions. I changed the 01’s to 02’s to see if it helped to use a different timer. After 1 minute do to confirm proper modules. You may not post new threads.

I recently added an extra keypad and reassigned all 3 keypads to 11,12 and Any idea why I cannot enter section ? Another issue is that I have set the front door for entry delay but it sets the alarm off immediately. The control panel has controlled and silenceable alarm outputs for the control of the bentek sirens, piezoelectric sirens, fire bells, flashers, telephone diallers, etc.

  JOKER LINGEN JUGENDSCHUTZFORMULAR PDF

Bentel j manual pdf

I tried the zone 4 door after arming and it behaved the same way bdntel continuous beep at the keypads and the bell went off immediately. Each detection zone is equipped with an alarm-repeat output for selective management in the event of fire. Tere, Kuidagi kindlast saan saata. Or default the panel programming and start over. Utiliza sau pentru a cauta zonele in cauza. I have re-entered the 30 second entry time, but still have problems.

Soon my ‘monitoring’ neighbor is going to give up on me!

Bentel J524-F tulekahju signakeskus

I had been opening the door immediately after arming because I had a house full of kids and didn’t want them to set off a motion sensor before I had a chance to check the door. Very simple really – I was not aware of the 4 second ‘fault’ period after the exit delay. Below the PC number is Rev 4A at least it looks like an ‘A’ but a solder pad obscures most of it.

Pe afisajul LCD se va afisa data, ora de activata. It has a six-zone main board that accepts up to three JESF expander boards for a total of 24 zones and detectors.

  1001 PIADAS PARA LER ANTES DE MORRER DE RIR PDF

Exactly what keystrokes did you enter to make the changes you described? I would go into installer program and press to reset the module list first. I’m a bit worried that I have assigned zone 1 to a keypad but since I can’t enter section I can’t ’00’ the keypad zones out.

Tere Kas Tartu saadate? Trying to hook up tire changer motor to switch. I think you may have swapped a good battery for a failing one. What is this old floor. Find all posts by j54f.

Zone betnel is supposed to be a smoke detector but I have since disconnected the input wire and made it null 00but the fault will not clear. Turn off light 6 in location It’s really easy to get one segment off with one of these benetl. DSC section locked out? Hmmm, if this was an ADT branded PC, they often have such specialty programming locations disabled from the programming.

I don’t know what this means